{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 10, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}}], "affected": [{"cpes": ["cpe:2.3:a:scadatec:procyon_scada:1.06:*:*:*:*:*:*:*", "cpe:2.3:a:scadatec:procyon_scada:1.13:*:*:*:*:*:*:*"], "vendor": "scadatec", "product": "procyon_scada", "versions": [{"status": "affected", "version": "1.06"}, {"status": "affected", "version": "1.13"}], "defaultStatus": "unaffected"}], "references": [{"url": "http://www.exploit-db.com/exploits/17827", "tags": ["exploit"]}, {"url": "http://secunia.com/advisories/45866", "tags": ["vendor-advisory"]}, {"url": "http://www.uscert.gov/control_systems/pdf/ICSA-11-216-01.pdf", "tags": ["x_us-government-resource"]}, {"url": "http://osvdb.org/75371"}, {"url": "http://securityreason.com/securityalert/8374"}, {"url": "http://www.securityfocus.com/bid/49480"}, {"url": "http://www.stratsec.net/Research/Advisories/Procyon-Core-Server-HMI-Remote-Stack-Overflow"}, {"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69632"}], "descriptions": [{"lang": "en", "value": "Core Server HMI Service (Coreservice.exe) in Scadatec Limited Procyon SCADA 1.06, and other versions before 1.14, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long password to the Telnet (TCP/23) port, which triggers an out-of-bounds read or write, leading to a stack-based buffer overflow."}, {"lang": "es", "value": "Core Server HMI Service (Coreservice.exe) en Scadatec Limited Procyon SCADA v1.06, y otras versiones antes de v1.14, permite a atacantes remotos provocar una denegación de servicio (caída) y posiblemente ejecutar cídgo de su elección a través de una contraseña larga para el puerto Telnet (TCP/23), lo que provoca una lectura o escritura fuera de límites que provoca un desbordamiento de búfer basado en pila."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-119", "description": "CWE-119"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2011-09-15T17:58:42Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2011-3322", "state": "PUBLISHED", "dateUpdated": "2025-04-11T00:51:21Z", "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "datePublished": "2011-09-15T17:58:42Z", "assignerShortName": "certcc"}, "dataVersion": "5.0"}