{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 4.3, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}}], "affected": [{"cpes": ["cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*"], "vendor": "schneider-electric", "product": "citecthistorian", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "4.30"}, {"status": "affected", "version": "4.20"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*"], "vendor": "schneider-electric", "product": "citectscada_reports", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "4.10"}, {"status": "affected", "version": "4.0"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*"], "vendor": "schneider-electric", "product": "vijeo_historian", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "4.30"}, {"status": "affected", "version": "4.0"}, {"status": "affected", "version": "4.10"}, {"status": "affected", "version": "4.20"}], "defaultStatus": "unaffected"}], "references": [{"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf", "tags": ["x_us-government-resource"]}, {"url": "http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695"}, {"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"}], "descriptions": [{"lang": "en", "value": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors."}, {"lang": "es", "value": "Desbordamiento de búfer en el control ActiveX TeeChart Steema, tal como se utiliza en Schneider Electric Vijeo Historian v4.30 y anteriores, CitectHistorian v4.30 y anteriores, y CitectSCADAReports v4.10 y anteriores, permite a atacantes remotos provocar una denegación de servicio a través de vectores no especificados."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-119", "description": "CWE-119"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2011-12-02T11:55:05Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2011-4033", "state": "PUBLISHED", "dateUpdated": "2025-04-11T00:51:21Z", "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "datePublished": "2011-12-02T11:55:05Z", "assignerShortName": "certcc"}, "dataVersion": "5.0"}