{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}}], "affected": [{"cpes": ["cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*"], "vendor": "schneider-electric", "product": "citecthistorian", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "4.30"}, {"status": "affected", "version": "4.20"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*"], "vendor": "schneider-electric", "product": "citectscada_reports", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "4.10"}, {"status": "affected", "version": "4.0"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*"], "vendor": "schneider-electric", "product": "vijeo_historian", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "4.30"}, {"status": "affected", "version": "4.0"}, {"status": "affected", "version": "4.10"}, {"status": "affected", "version": "4.20"}], "defaultStatus": "unaffected"}], "references": [{"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf", "tags": ["x_us-government-resource"]}, {"url": "http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695"}, {"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"}], "descriptions": [{"lang": "en", "value": "Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors."}, {"lang": "es", "value": "Vulnerabilidad de salto de directorio en Schneider Electric Vijeo Historian v4.30 y anteriores, CitectHistorian v4.30 y anteriores, y CitectSCADAReports v4.10 y anteriores permite a atacantes remotos leer ficheros arbitrarios a través de vectores no especificados."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-22", "description": "CWE-22"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2011-12-02T11:55:05Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2011-4036", "state": "PUBLISHED", "dateUpdated": "2025-04-11T00:51:21Z", "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "datePublished": "2011-12-02T11:55:05Z", "assignerShortName": "certcc"}, "dataVersion": "5.0"}