{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}}], "affected": [{"cpes": ["cpe:2.3:a:honeywell:enterprise_building_manager:r400:*:*:*:*:*:*:*", "cpe:2.3:a:honeywell:enterprise_building_manager:r410.1:*:*:*:*:*:*:*"], "vendor": "honeywell", "product": "enterprise_building_manager", "versions": [{"status": "affected", "version": "r400"}, {"status": "affected", "version": "r410.1"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:honeywell:experion:r200:*:*:*:*:*:*:*", "cpe:2.3:a:honeywell:experion:r300:*:*:*:*:*:*:*", "cpe:2.3:a:honeywell:experion:r310:*:*:*:*:*:*:*", "cpe:2.3:a:honeywell:experion:r400.0:*:*:*:*:*:*:*"], "vendor": "honeywell", "product": "experion", "versions": [{"status": "affected", "version": "r200"}, {"status": "affected", "version": "r300"}, {"status": "affected", "version": "r310"}, {"status": "affected", "version": "r400.0"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:honeywell:symmetre:r410.1:*:*:*:*:*:*:*"], "vendor": "honeywell", "product": "symmetre", "versions": [{"status": "affected", "version": "r410.1"}], "defaultStatus": "unaffected"}], "references": [{"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-150-01.pdf", "tags": ["third-party-advisory", "x_us-government-resource"]}, {"url": "https://www.honeywellprocess.com/en-US/support/pages/all-notifications.aspx", "tags": ["vendor-advisory"]}], "descriptions": [{"lang": "en", "value": "Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors."}, {"lang": "es", "value": "Desbordamiento de búfer en el control ActiveX HMIWeb Browser HSCDSPRenderDLL en Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, y R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 y R410.1; y Honeywell Environmental Combustion y Controls (ECC) SymmetrE R410.1 permite a atacantes remotos a ejecutar código a través de vectores no especificados."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-787", "description": "CWE-787"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2012-09-08T10:28:19Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2012-0254", "state": "PUBLISHED", "dateUpdated": "2025-04-11T00:51:21Z", "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "datePublished": "2012-09-08T10:28:19Z", "assignerShortName": "certcc"}, "dataVersion": "5.0"}