{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 7.7, "accessVector": "ADJACENT_NETWORK", "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "authentication": "SINGLE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}}], "affected": [{"vendor": "unknown", "product": "unknown", "defaultStatus": "unknown"}], "references": [{"url": "http://www.kb.cert.org/vuls/id/441363", "tags": ["x_us-government-resource"]}], "descriptions": [{"lang": "en", "value": "lhn/public/network/ping in HP SAN/iQ 9.5 on the HP Virtual SAN Appliance allows remote authenticated users to execute arbitrary commands via shell metacharacters in the (1) first, (2) third, or (3) fourth parameter.  NOTE: this vulnerability exists because of an incomplete fix for CVE-2012-4361."}, {"lang": "es", "value": "lhn/public/network/ping en HP SAN/iQ v9.5 en HP Virtual SAN Appliance permite a usuarios remotos autenticados ejecutar comandos arbitrarios a través de meta caracteres en una consola en el (1) primer, (2) tercer o (3) cuarto parámetro. NOTA: esta vulnerabilidad se produce debido una solución incompleta para la vulnerabilidad CVE-2012-4361."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-78", "description": "CWE-78"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "DISCARDED_CNA", "dateUpdated": "2012-08-20T22:55:00Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2012-2986", "state": "PUBLISHED", "dateUpdated": "2025-04-11T00:51:21Z", "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "datePublished": "2012-08-20T22:55:00Z", "assignerShortName": "certcc"}, "dataVersion": "5.0"}