{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}}], "affected": [{"cpes": ["cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*"], "vendor": "siemens", "product": "simatic_pcs7", "versions": [{"status": "affected", "version": "8.0"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*"], "vendor": "siemens", "product": "wincc", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "7.0"}, {"status": "affected", "version": "5.0"}, {"status": "affected", "version": "6.0"}, {"status": "affected", "version": "7.0"}], "defaultStatus": "unaffected"}], "references": [{"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf", "tags": ["patch", "vendor-advisory"]}, {"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf", "tags": ["x_us-government-resource"]}, {"url": "http://en.securitylab.ru/lab/PT-2012-43"}], "descriptions": [{"lang": "en", "value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request."}, {"lang": "es", "value": "WebNavigator en Siemens WinCC v7.0 SP3 y anteriores, como las usadas en SIMATIC PCS7 y otros productos, almacena información sensible bajo l directorio web raiz con un control de acceso no suficiente, lo que permite a atacantes remotos a leer (1) ficheros de registro o (2) ficheros de configuración a través de una petición directa."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-264", "description": "CWE-264"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2012-09-18T14:55:01Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2012-3030", "state": "PUBLISHED", "dateUpdated": "2025-04-11T00:51:21Z", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "datePublished": "2012-09-18T14:55:01Z", "assignerShortName": "icscert"}, "dataVersion": "5.0"}