{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 7.1, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "MEDIUM", "availabilityImpact": "COMPLETE", "confidentialityImpact": "NONE"}}], "affected": [{"cpes": ["cpe:2.3:a:catapultsoftware:catapult_dnp3_i\\/o_driver:*:*:*:*:*:*:*:*"], "vendor": "catapultsoftware", "product": "catapult_dnp3_i\\/o_driver", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "7.20.56"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:*:j:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:-:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:a:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:b:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:c:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:d:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:e:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:f:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:g:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:h:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\/o_driver:7.20:i:*:*:*:*:*:*"], "vendor": "ge", "product": "intelligent_platforms_proficy_dnp3_i\\/o_driver", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "7.20"}, {"status": "affected", "version": "7.20"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:4.01:*:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:7.5:*:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.0:*:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.1:*:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:8.2:*:*:*:*:*:*:*"], "vendor": "ge", "product": "intelligent_platforms_proficy_hmi\\/scada_cimplicity", "versions": [{"status": "affected", "version": "4.01"}, {"status": "affected", "version": "7.5"}, {"status": "affected", "version": "8.0"}, {"status": "affected", "version": "8.1"}, {"status": "affected", "version": "8.2"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.0:*:*:*:*:*:*:*", "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.1:*:*:*:*:*:*:*"], "vendor": "ge", "product": "intelligent_platforms_proficy_hmi\\/scada_ifix", "versions": [{"status": "affected", "version": "5.0"}, {"status": "affected", "version": "5.1"}], "defaultStatus": "unaffected"}], "references": [{"url": "http://support.ge-ip.com/support/index?page=kbchannel&id=S:KB15805", "tags": ["vendor-advisory"]}, {"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf", "tags": ["vendor-advisory"]}, {"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01", "tags": ["x_us-government-resource"]}, {"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02", "tags": ["x_us-government-resource"]}], "descriptions": [{"lang": "en", "value": "The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet."}, {"lang": "es", "value": "El driver (1) Catapult DNP3 I/O anterior a la versión 7.2.0.60 y (2) el driver GE Intelligent Platforms Proficy DNP3 I/O anterior a 7.20k, tal y como se usa en DNPDrv.exe (también conocido como servidor de estación maestro DNP) en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY e iFIX, permite a atacantes remotos provocar una denegación de servicio (bucle infinito) a través de paquetes DNP3 TCP manipulados."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-20", "description": "CWE-20"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2013-11-22T01:55:03Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2013-2811", "state": "PUBLISHED", "dateUpdated": "2025-04-11T00:51:21Z", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "datePublished": "2013-11-22T01:55:03Z", "assignerShortName": "icscert"}, "dataVersion": "5.0"}