{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}}], "affected": [{"cpes": ["cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*", "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*", "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*"], "vendor": "siemens", "product": "simatic_pcs7", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "8.0"}, {"status": "affected", "version": "7.1"}, {"status": "affected", "version": "8.0"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:wincc:7.1:sp1:*:*:*:*:*:*"], "vendor": "siemens", "product": "wincc", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "7.2"}, {"status": "affected", "version": "5.0"}, {"status": "affected", "version": "6.0"}, {"status": "affected", "version": "7.0"}, {"status": "affected", "version": "7.1"}], "defaultStatus": "unaffected"}], "references": [{"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf", "tags": ["vendor-advisory"]}], "descriptions": [{"lang": "en", "value": "The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request."}, {"lang": "es", "value": "El servidor WebNavigator en Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, permite a atacantes remotos obtener información sensible a través de una solicitud HTTP."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-200", "description": "CWE-200"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2014-07-24T14:55:08Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2014-4682", "state": "PUBLISHED", "dateUpdated": "2025-04-12T10:46:40Z", "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "datePublished": "2014-07-24T14:55:08Z", "assignerShortName": "mitre"}, "dataVersion": "5.0"}