{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "NONE"}}, {"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 6.4, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}}], "affected": [{"cpes": ["cpe:2.3:a:aveva:clearscada:2010:r3.1:*:*:*:*:*:*", "cpe:2.3:a:aveva:clearscada:2010:r3:*:*:*:*:*:*", "cpe:2.3:a:aveva:clearscada:2013:r1.1:*:*:*:*:*:*", "cpe:2.3:a:aveva:clearscada:2013:r1.1a:*:*:*:*:*:*", "cpe:2.3:a:aveva:clearscada:2013:r1.2:*:*:*:*:*:*", "cpe:2.3:a:aveva:clearscada:2013:r1:*:*:*:*:*:*", "cpe:2.3:a:aveva:clearscada:2013:r2:*:*:*:*:*:*"], "vendor": "aveva", "product": "clearscada", "versions": [{"status": "affected", "version": "2010"}, {"status": "affected", "version": "2013"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:a:schneider-electric:scada_expert_clearscada:2013:r2.1:*:*:*:*:*:*", "cpe:2.3:a:schneider-electric:scada_expert_clearscada:2014:r1:*:*:*:*:*:*"], "vendor": "schneider-electric", "product": "scada_expert_clearscada", "versions": [{"status": "affected", "version": "2013"}, {"status": "affected", "version": "2014"}], "defaultStatus": "unaffected"}], "references": [{"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-259-01", "tags": ["third-party-advisory", "x_us-government-resource"]}, {"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-259-01a.json"}, {"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-259-01a"}], "descriptions": [{"lang": "en", "value": "Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm."}, {"lang": "es", "value": "Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 hasta 2014 R1 utiliza el algoritmo MD5 para certificados X.509, lo cual facilita a atacantes remotos falsificar servidores a través de ataques criptográficos contra este algoritmo"}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-310", "description": "CWE-310"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2014-09-18T10:55:11Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2014-5413", "state": "PUBLISHED", "dateUpdated": "2025-11-04T23:15:33Z", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "datePublished": "2014-09-18T10:55:11Z", "assignerShortName": "icscert"}, "dataVersion": "5.0"}