{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 6.4, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}}, {"format": "CVSS", "cvssV3_0": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 8.6, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "NONE", "confidentialityImpact": "LOW"}}], "affected": [{"cpes": ["cpe:2.3:o:honeywell:midas_black_firmware:*:*:*:*:*:*:*:*"], "vendor": "honeywell", "product": "midas_black_firmware", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "2.13b1"}], "defaultStatus": "unaffected"}, {"cpes": ["cpe:2.3:o:honeywell:midas_firmware:*:*:*:*:*:*:*:*"], "vendor": "honeywell", "product": "midas_firmware", "versions": [{"status": "affected", "version": "0", "versionType": "custom", "lessThanOrEqual": "1.13b1"}], "defaultStatus": "unaffected"}], "references": [{"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-309-02", "tags": ["third-party-advisory", "x_us-government-resource"]}], "descriptions": [{"lang": "en", "value": "Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and write to a configuration file or trigger a calibration or test, via unspecified vectors."}, {"lang": "es", "value": "Vulnerabilidad de salto de directorio en el servidor web en los detectores de gas de Honeywell Midas en versiones anteriores a 1.13b3 y en detectores de gas de Midas Black en versiones anteriores a 2.13b3 permite a atacantes remotos eludir la autenticación y escribir a un archivo de configuración o desencadenar una calibración o una prueba a través de vectores no especificados."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-22", "description": "CWE-22"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "nvd", "dateUpdated": "2015-12-21T11:59:09Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2015-7907", "state": "PUBLISHED", "dateUpdated": "2025-04-12T10:46:40Z", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "datePublished": "2015-12-21T11:59:09Z", "assignerShortName": "icscert"}, "dataVersion": "5.0"}