{"dataType": "CVE_RECORD", "containers": {"cna": {"metrics": [{"format": "CVSS", "cvssV2_0": {"version": "2.0", "baseScore": 7.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "NONE"}}, {"format": "CVSS", "cvssV3_0": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}}], "affected": [{"vendor": "unknown", "product": "unknown", "defaultStatus": "unknown"}], "references": [{"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20160113-02-switch-en", "tags": ["vendor-advisory"]}], "descriptions": [{"lang": "en", "value": "Memory leak in Huawei S5300EI, S5300SI, S5310HI, S6300EI/ S2350EI, and S5300LI Campus series switches with software V200R001C00 before V200R001SPH018, V200R002C00 before V200R003SPH011, and V200R003C00 before V200R003SPH011; S9300, S7700, and S9700 Campus series switches with software V200R001C00 before V200R001SPH023, V200R002C00 before V200R003SPH011, and V200R003C00 before V200R003SPH011; and S2300 and S3300 Campus series switches with software V100R006C05 before V100R006SPH022 allows remote attackers to cause a denial of service (memory consumption and reboot) via a large number of ICMPv6 packets."}, {"lang": "es", "value": "Fuga de memoria en switches Huawei de la serie Campus S5300EI, S5300SI, S5310HI, S6300EI/ S2350EI y S5300LI con software V200R001C00 en versiones anteriores a V200R001SPH018, V200R002C00 en versiones anteriores a V200R003SPH011 y V200R003C00 en versiones anteriores a V200R003SPH011; switches de la serie Campus S9300, S7700 y S9700 con software V200R001C00 en versiones anteriores a V200R001SPH023, V200R002C00 en versiones anteriores a V200R003SPH011 y V200R003C00 en versiones anteriores a V200R003SPH011; y switches de la serie Campus S2300 y S3300 con software V100R006C05 en versiones anteriores a V100R006SPH022 permite a atacantes remotos causar una denegación de servicio (consumo de memoria y reinicio) a través de un gran número de paquetes ICMPv6."}], "problemTypes": [{"descriptions": [{"lang": "en", "cweId": "CWE-119", "description": "CWE-119"}, {"lang": "en", "cweId": "CWE-399", "description": "CWE-399"}]}], "providerMetadata": {"orgId": "00000000-0000-4000-A000-000000000003", "shortName": "DISCARDED_CNA", "dateUpdated": "2016-04-14T15:59:02Z", "x_subShortName": "nvd"}}}, "cveMetadata": {"cveId": "CVE-2015-8676", "state": "PUBLISHED", "dateUpdated": "2025-04-12T10:46:40Z", "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "datePublished": "2016-04-14T15:59:02Z", "assignerShortName": "mitre"}, "dataVersion": "5.0"}